MU50 Bulk Dump procedure

    1) Make sure that the MU50 is properly connected to the device that will be receiving the Bulk Dump data.

    2) Set the [HOST SELECT] switch to the appropriate setting: 'MIDI' for connections using MIDI In and MIDI Out; 'PC2' for serial connections to a PC; or 'MAC' for serial connections to a MAC.

    3) Press the [UTIL] button.

    4) Select 'DUMPOUT'.

    5) Press the [ENTER] button.

    6) Select 'All', 'Multi' or 'Performance' from the 'Dump Out' menu to specify the type of data to be sent.

    7) Press the [ENTER] button.

    8) When the 'Are you sure?' prompt appears, press the [ENTER] button to execute the operation, or press the [EXIT] to cancel and return to the 'Dump Out' menu.

    Reference: Owner's Manual, p.98-101