Search
Network
TXn Series Amplifiers – NEW!  
Tn Series Amplifier  
XP Series Power Amplifier  
PC-1N Series   
XM Series  
XH200  
NHB32-C  
ACU16-C  
Standard
OR
Tn Series Amplifier
Tn AmplifierPower Amplifier comes with 3 models: T5n, T4n and T3n.

Promo Video
Flashplayer 8 Required
Enlarge Picture
Features  Specifications  Dimensions  Panel Views  Brochure  
General Specifications T5n T4n T3n
Output Power (W) 120V(US) 230V(EU) 120V(US) 230V(EU) 120V(US) 230V(EU)
  1kHz
THD+N=1%
2Ω per channel 2500 2500 2200 2200 1900 1900
4Ω per channel 2200 2300 1950 2050 1400 1400
8Ω per channel 1350 1350 1150 1150 800 800
4Ω bridge 5000 5000 4400 4400 3800 3800
8Ω bridge 4400 4600 3900 4100 2800 2800
1kHz
20mS burst
2Ω per channel 3400 3400 2900 3100 2200 2150
4Ω per channel 2200 2300 1950 2050 1400 1400
8Ω per channel 1350 1350 1150 1150 800 800
4Ω bridge 6800 6800 5800 6200 4400 4300
8Ω bridge 4400 4600 3900 4100 2800 2800
SN ratio 20Hz-20kHz (DIN AUDIO) 107dB 106dB 105dB
Power consumption (W) Stand-by 5 5 5
Idle 70 70 70
1/8 (2Ω/Pink noise) 1600 1600 1400 1400 1200 1200
1/8 = Power consumption at 1/8 maximum output power

All Models
THD+N 20Hz-20kHz,
Half Power RL-4Ω, 8Ω
0.1%
Intermodulation Distortion 60Hz: 7kHz, 4:1, Half Power 0.1%
Frequency response
RL=8Ω,Po=1W,HPF=OFF
20Hz-20kHz
MAX
TYP
MIN
0dB
0dB
6dB
ChannelHalf Power RL=8Ω,1kHz
SeparationAtt. max input 600Ω shunt
70dB
Residual Noise Att,min 20Hz-20kHz(DIN AUDIO) -70dBu
Damping factorRL=8Ω 1kHz 800
Voltage GainAtt.max 26dB
Maximum Input Voltage +24dBu
Input Impedence 20kΩ (balance) 10kΩ (unbalance)
Controls Front Panel POWER switch(push on/push off)
attenuator (31 position) x2
Rear Panel MODE switch
(STEREO/BRIDGE/PARALLEL) X1
HPF switch
(20Hz/OFF 12dB/oct) x1
AMP ID switch
(6PDIP) x1
Connectors Input XLR-3-31 type/ch
Euroblock connector
(balance)/ch
Output SPEAKON/ch, 5way biding postx1
DATA PORT RJ45x2
Indicators POWER/STANDBY x1 (Green/Orange)
REMOTE x1 (Green)
PROTECTION x1 (Red)
TEMP x1 (Red) heatsink temp Greater Than Or Equal To Graphic 85°C
SIGNAL x2 (Green)
MUTE x2 (Red)
CLIP/LIMIT x2 (Red)
Load protection POWER switch on/off mute
DC-fault: power supply shutdown / do not return automatically.
clip limiting: THD greater than or equal to sign 0.5%
Amplifier protection thermal: cut the output (heatsink
temp greater than or equal to sign 90°C) return automatically.
VI limiter (RL Less than or equal to sign 1Ω): Limit the output
Power supply protection thermal: power supply shutdown (heatsink temp greater than or equal to sign 100°C) do not return.
Cooling Variable-speed fan: x2
Power requirements US&CANADA: 120V/60Hz
EUROPE: 230V/50Hz
Dimensions (WxHxD) 480 x 88 x 456mm (2U)
Weight 14.0kg